Ziton Enhanced Conventional Fire and Extinguishing Panel - 3 Zone (ZP1-X3E-03)
The Ziton ZP1-X3E is a networkable, enhanced conventional fire alarm and extinguishing control panel with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition, the panel offers supervised outputs for first stage notification, second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification, as well as multiple inputs for system control.
The panels support 2 types of auxiliary relay boards, one with 4 standard relays, and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.
The ZP1-X3E supports class A (redundant ring) and B (standard bus) networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system, providing superior flexibility in system organisation and planning.
• EN54:2, EN54:4 and CE approved
• CPR certified
• EN12094-1 certified
• WEEE compliant
• RoHS compliant
Key Features |
---|
> Easily removable parts > Normal & head-out supervision support per zone > 3 x detection zones > Single zone, double zone or any combination of zones configurable for release > 6 Pre-configured relays and 8 supervised inputs for extinguishing control > Configurable fire routing, sounder, extinguishing, reset and door monitoring delays > Configurable "Hold Mode" type-A or type-B > Sounders configurable for pulsing or continuous operation > Extinguishing agent flow confirmation > Continuous or resettable 24 VDC auxiliary supply > Auxiliary standard & supervised relay output support > Default support for special functions such as: - EN54 compliant user access levels - Basic & Advanced level configuration - mixed zones - front panel diagnostics with test & disable control - one-man walk test > Redundant networking to ZP1 conventional and ZP2 addressable nodes > Intrinsically safe and EN54-13 zone support > For small to mid-sized conventional applications |
Manufacturer | Ziton |
---|---|
MPN | ZP1-X3E-03 |
Write Your Own Review
![Loading...](https://www.safefiredirect.co.uk/static/version1719466362/frontend/Alothemes/electro2s/en_GB/MageArray_ProductQuestions/images/loader.gif)
Sort By:
No questions yet. Be the first to ask the question!
Code: | ZP1-X3E-03 |
Description: | Ziton Enhanced Conventional Fire and Extinguishing Panel - 3 Zone |
Dimensions: | W:440mm x H:480mm x D:140mm |
Form factor: | Medium |
Max. system capacity: | up to 2016 devices |
Network size (nodes): | up to 21 |
Operating voltage: | 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%) |
Current consumption: | 3.15 A @ 110/1.5 A @ 240 VAC |
Max. loop capacity: | 3 |
Max. zone capacity: | up to 3; 32 max devices per zone |
Standby battery capacity: | 2 x 12V 12 Ah (SLA) |
Operating temperature: | -5 to +40°C |
Storage temperature: | -20 to +70°C |
Relative humidity: | 10 to 95% non condensing |
IP rating: | IP30, Indoor |
Input supply: | Cable spec: 3 x 1.5 mm² (live, neutral, earth) |
Panel supply: | 4A @ 24 VDC Quiescent current (no devices): 0.39A Alarm current (no devices): 2.78A |
Zones: | 3 Output voltage: 22 VDC (18-24 VDC) Load (max): 65 mA Cable resistance (max): 40 ohm Cable capacitance (max): 500 nF Devices per zone (max): 32 |
Supervised inputs: | 6 Use: MCP Start, MCP Hold, MCP Abort, Pressure Switch, Gas Flow, Door Monitor |
Non-supervised inputs: | 2 Use: Auto/Manual mode, Remote Reset |
Supervised outputs: | 4 Use: Fire Sounders, Extinguishing Sounders, Optical Indications, Actuator Notification: 2 x 500 mA @ 24 VDC Visual indicators: 1 x 500 mA @ 24 VDC Actuator: 1 x 1A @ 24 VDC |
Non Supervised outputs: | 4 Use: Hold Mode, Abort Mode, Manual Mode, Release Indication Specification: 6 x 2 A @ 30 V |
Aux. Supply output: | Output voltage: 24 VDC (21-28 VDC) Load (max): 250 mA |
Colour: | Grey (RAL 7035) |
Mounting type: | Surface |
Cable entries: | Ø 20 mm - 14 / 2 / 12 (Top/Bottom/Rear) |
Regulatory: | CPD, RoHS, WEEE compliant EN12094-1, EN54-2, EN54-4 certified |