Kidde AlarmLine II Analogue EN Controller (AAECU) and AlarmLine II Analogue EN end of line unit (AAECU-EOL). The controller monitors an AlarmLine II Analogue EN LHD sensor cable, configuration of alarm and pre-alarm temperatures as well as enabling simple interface to a main fire alarm or BMS system. It provides LED indications as well as an LCD. Internal push buttons allow for easy configuration without the need for a PC. Configuration via PC is also supported via a USB connection and optional configuration software AAECU-PCC.

Each control unit may have up to 500m of LHD sensor cable connected to it, acting as a single detection zone.The AAECU is supplied with an End-Of-Line unit (AAECU-EOL). The End-Of-Line unit is also available separately as a spare part.A junction box (AAECU-JUN) is also available separately should two pieces of cable need to be joined.


Key Features
> VdS EN54-22:2015/prA1:2007
> Up to 500m of sensor cable per zone
> Separate pre-alarm and alarm signals
> Easy programmable interface
> Enclosure temperature alarm
> IP65 rated enclosure
More Information
ManufacturerKidde Alarmline
MPNAAECU
Write Your Own Review
You're reviewing:Kidde Alarmline EN 54-22 Analogue LHD Composite Control Unit
Your Rating
Loading...

Sort By: 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!
Code: AAECU
Description: Kidde AlarmLine II Analogue EN Control Unit
Dimensions: Controller : W:182mm x H:180mm x D:90mm
EOL unit : W:100mm x H:60mm x D:35mm
Electrical: Operating voltage: 20 to 30 VDC
Power consumption: 2W max.
Power supply type: External
Current consumption: 59 mA at 30 VDC
General: Status indication: 4 x LED's (power,​ fault,​ pre-alarm & alarm)
User interface: LCD display with internal configuration buttons
Reset voltage: 5-28 VDC for minimum 3 seconds
Detection: Principle: Heat - Classes A1I/A2I & BI
Alarm temperature: +54°C (min.), +100°C (max.)
Input: Quantity: 1 for remote reset
Type / rating: 5-28 VDC (at 2 mA) for minimum 3 seconds
Output: Quantity: 3 for fault,​ pre-alarm and alarm
Type / rating: Pre-alarm and alarm : relay with NO/NC/C connections (2 A at 30 VDC),​ Fault : NC opto-isolated phototransistor output
Colour: Light grey
Mounting type: Surface, Wall
Material: Polycarbonate
Environment: Controller : -20 to +50°C
EOL unit : -40 to +125°C
IP Rating: Controller : IP65 (IK08)
               EOL unit : IP65
Regulatory: CE,​ EN54-22,​ VdS​ certified
Weight (net): Controller 860 g
EOL unit : 115 g