Kentec Sigma XT Extinguishant Control Panel (K11031M2)
The Kentec Sigma XT Extinguishant Control Panel (K11031M2) is suitable for small to medium fixed firefighting installations. This single area panel has 3 detection zones and the extinguishant release can be configured to activate from any combination of detection zone inputs.
Sigma XT panels are both robust and easy to install having all the electronics mounted on a single, easily removable, steel plate.
Key Features |
---|
> Single or any combination of zones can be configured to release > Configurable first stage sounder delays > Configurable detection delays > Zero time delay upon manual release option > Compatible with I.S. barriers > Non-latching zone input option to receive signals from other systems e.g. aspirating equipment > Countdown timer shows time remaining until release > Supports up to 7 x 4-wire status indicators > Configurable extinguishant delays up to 60 seconds in 5 second steps > Configurable extinguishant duration up to 5 minutes in 5 second steps > Built-in extract fan control > EN12094-1, EN54-2 and EN54-4 Approved |
Manufacturer | Kentec Electronics |
---|---|
MPN | K11031M2 |
Write Your Own Review
Sort By:
No questions yet. Be the first to ask the question!
Product Code: | K11031M2 |
Product Dimensions: | W:385mm x H:310mm x D:90mm Surface mounting panel |
Construction: | 1.2mm mild sheet steel surface mount enclosure |
IP Rating: | IP30 |
Finish: | Epoxy powder coated |
Colour: | lid & box BS 00 A 05 grey - fine texture control plates & labels RAL 7047 light grey - satin |
Weight: | 6kg |
Mains supply: | 230V AC +10%/-15% (100W max) |
Mains supply fuse: | 1.6Amp (F1.6A L250V) |
Power supply rating: | 3 Amps total including battery charge 28V +/- 2V |
Maximum ripple current: | 200 millivolts |
Battery type (Yuasa NP): | 2 x 12V sealed lead acid in series |
Battery charge voltage: | 27.6V DC nominal (temperature compensated) |
Battery charge current: | 0.7A maximum |
Battery fuse: | 20mm, 3.15A glass |
Maximum current draw from batteries: | 3 Amps |
Quiscent current of panel in mains fail: | 0.095A |
ROV output: | Fused at 500mA with electronic fuse |
Sounder outputs | 24V Fused at 500mA with electronic fuse |
Fault relay contact rating: | 30V DC 1A maximum |
Fire relay contact rating: | 30V DC 1A maximum |
Local fire relay contact rating: | 30V DC 1A maximum |
First stage contact rating: | 30V DC 1A maximum |
Second stage contact rating: | 30V DC 1A maximum |
Extract contact rating: | 30VDC 1A maximum |
Zone quiescent current: | 2mA maximum |
Terminal capacity: | 0.5mm2 -2.5mm2 solid or stranded wire |
No. of detectors per zone: | Dependent on type (max. 32) |
No. of sounders per circuit: | Dependent on type (max 0.5A per sounder circuit) |
Detection circuit end of line: | 6K8 5% ½ W resistor |
Monitored input end of line: | 6K8 5% ½ W resistor |
Sounder circuit end of line: | 10K 5% ¼ W resistor |
Extinguishant output end of line: | 1N4004 diode |
No. of sounder circuits: | 2 x 1st stage, 1 x 2nd stage |
No. of detection circuits: | 3 |
Extinguishant release output: | Fused at 1 Amp |
Extinguishant release delay: | Adjustable 0 to 60 seconds (in 5 second steps) |
Extinguishant release duration: | Adjustable 60 to 300 seconds (in 5 second steps) |
SIL, AL, FLT, RST inputs: | Switched -ve, max resistance 100 Ohms |
Detector alarm threshold: | 999 ohms to 400 ohms |
Call point alarm threshold: | 399 ohms to 100 ohms |
Short circuit threshold: | 99 ohms to 0 ohms |
Head removal condition: | 15.5 to 17.5 volts |
Cabling: | FP200 or equivalent |
Monitored inputs normal threshold: | 8K Ohm to 1K Ohm |
Monitored inputs alarm threshold: | 999 ohms to 100 ohms |
Monitored inputs short circuit threshold: | 99 ohms to 0 ohms |
Status Indicator/Ancillary board connection: | Two wire RS485 connection |
Status unit power output | Fused at 500mA with electronic fuse |