This website uses cookies to ensure you get the best experience on our website. Read our cookie policy
SKU
ORION-8
£183.31 £152.76
Global Fire ORION 8 Zone Conventional Fire Panel
The ORION-8 is an 8 zone conventional fire alarm control panel.
The ORION conventional control panel range from Global Fire Equipment (GFE) offers a creatively designed and visually pleasing solution for smaller cost-conscious projects demanding simplicity of operation. Versions available include 2. 4 and 8 zone panels and two styles of repeater.
The outstanding programmable features included in this panel range contradict the facilities commonly available in this type of panel an include: Programmable time delay per zone; Day/Night operation mode; Selectable non-latching zones; Coincidence detection.
Operation is extremely intuitive, offering simple control and one-button disablement facilities, as well as the One Man Test mode, which provides simple and efficient testing of the system.
Advanced configuration solutions, that gives one of the most highly advanced levels of system integration and compatibility existing on the market at this level, include the following: dedicated RS232 / RS485 communication interface allowing the connection of up to 4 remote repeater panels; Addressable loop interface modules and multiplexed zonal output relays and sounder modules.
Key Features |
---|
> 8 conventional detection zones - non-expandable > Up to 32 conventional devices (smoke and/or heat detectors and call-points) per zone > Active End of Line for Zone wiring monitoring (10uF/50V bipolar capacitor) > Programmable non-latching zones (selectable for each zone) > Programmable delay timer for sounder activation (maximum of 8m) > Day/Night function > Delayed operation (selectable for each zone) > Zone Coincidence (programmable for adjacent zones) > Two Access Levels (Selectable by fixed code entry) > One man test capability > Supervised auxiliary 24-volt supply output > 2 Supervised/monitored sounder circuits > 3 Remote Inputs (Class Change, Remote Reset and Day/Night Operation) > 2 Relay outputs for fire and fault status indication (Unmonitored) > Dedicated repeater panel and analogue loop interface > Additional output via MPX-REL & MPX-SNDR modules > EN54-2 and EN54-4 compliant |
Manufacturer | Global Fire Equipment |
---|---|
MPN | ORION 8 |
Write Your Own Review
Sort By:
No questions yet. Be the first to ask the question!
PRIMARY SUPPLY VOLTAGE – IN | 230V AC +10% -15% |
PRIMARY SUPPLY VOLTAGE- OUT | 28.5V DC nominal |
PRIMARY SUPPLY CURRENT-OUT | 1.7A @ 28.5V DC nominal (max.) |
SECONDARY SUPPLY VOLTAGE | 21.0 min. – 27.2 max. V DC – BAT charger o/p 28V DC |
SECONDARY SUPPLY CURRENT OUTPUT | 1.85 Amp maximum @ 20 o C |
INTERNAL BATTERY CAPACITY – MAXIMUM | 2 x 12V x 7Ah Sealed VRLA Lead Acid Batteries |
MAINS FUSE | 4 A 250 V Slow Blow – 20 mm |
BATTERY FUSE | 1.85 Amp – Resettable |
NUMBER OF DETECTION ZONES | 8 |
ZONE CURRENT – QUIESCENT / ALARM | 10 mA / 60 mA maximum |
MAX. CABLE RESISTANCE / CAPACITANCE | 40 Ohms / 0.470 uF |
END OF LINE MONITORING | Active EOL – 10uF/50V Bipolar Capacitor |
BS5839 DETECTOR REMOVAL COMPLIANT | YES provided diodes are fitted to detector base |
DEVICES PER ZONE | 32 maximum – EN54 pt.2 |
ALARM RESISTANCE VALUE: INPUTS | 270 – 1000 Ohms |
MAXIMUM CURRENT: OUTPUTS | 1,85A maximum current drive for both S1 & S2 circuits; 100 mA for RM output |
VOLTAGE OUTPUT | 27.5V DC nominal |
END OF LINE RESISTOR: S1 & S2; RM | S1 & S2: 10K Ohms – 1/4 Watt; RM: 4K7 Ohms – 1/4 Watt |
AUXILIARY RELAY OUTPUT | 1 Fire (COM-NC-NO) – 1 Fault (COM-NC) non-supervised |
RELAY CONTACT RATING | 30V DC – 2A / 230V AC – 0.25A (resistive loads) |
EVACUATION AND RESET | Non-Latching – Voltage free contact |
MAXIMUM HUMIDITY | 95% RH Non-Condensing |
PROTECTION RATING | IP30 |
OPERATING TEMPERATURE | -10ºC to 50ºC |
WEIGHT | 1.7 Kg – 7 Kg (inc. 2 x 7 AH 12 V bat.) |
DIMENSIONS | 273 (L) x 107 (W) x 404 (H) mm |
COLOUR | White |