GENT Xenex 2 Zone Conventional Fire Panel (13270-02LB)

SKU
13270-02LB
£228.54 £190.45
GENT Xenex 2 Zone Conventional Fire Panel (13270-02LB)

The GENT Xenex 2 Zone Conventional Fire Alarm Panel (13270-02LB) is BSI approved to EN54: Parts 2 & 4 and can be used on installations meeting BS5839:Part 1 specifications.

Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.

Utilising LPCB-approved conventional smoke or heat detectors, GENT Xenex panels offer exceptional value for money.


Key Features
> Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
> Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed temperature or rate of rise types), sounders, strobes and bells
> Sounder options include shallow base, deep base and bedhead sounder types
> For installations where a high degree of weatherproofing is required, IP55-rated sounders, sirens and bells are available
> Common accessories such as manual call points (standard IP54 rated or key-operated anti-vandal types, available as either surface-mounted or flush-fitted models), door release units and Xenon fl ashers can all be accommodated
> Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
More Information
ManufacturerGENT
MPN13270-02LB
Primary Power SourceMains Powered (230V)
System TypeConventional
Number of Zones2
ColourGrey
WarrantyN/A
Write Your Own Review
You're reviewing:GENT Xenex 2 Zone Conventional Fire Panel (13270-02LB)
Your Rating
Loading...

Sort By: 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!
No of Zones
Max Load per Zone3mA
No of Sounder Circuits2
Max Sounder Circuit Load500mA per circuit max 1A combined
Batteries2 x 12v 3.2Ah
Battery Standby72 hours (1mA per zone + 0.5A sounder load max)
Weight (approx with batteries)5.8kg
Cable TypeBS 6387, 2 core, min 1.5mm2 CSA
Operating EnvironmentIndoor, 0 - 40ºC
Class Change FacilityVolt free contact - max distance 100m
ApprovalsBSI Approved (KM 553763)
CPD No0086-CPD-553764
Relevant StandardEN54: Parts 2 & 4
Max no of Repeaters per system1