SKU
HAK/1
£241.18 £200.98
C-TEC Hush ActiV Grade C Domestic Fire Alarm Kit (HAK/1)
A new Grade C domestic fire detection and alarm system to BS 5839-6 (2019) for use in individual flats, houses and apartments.
The HAK/1 Kit Includes:
- 1 x Double Gang Hush-ActiV Controller c/w 72 hour standby battery
- 1 x Double Gang 230V/24V 250mA PSU
- 1 x ActiV multi sensor
- 1 x ActiV smoke detector
- 1 x ActiV 60ºC heat detector
- 3 x ActiV diode detector bases
- 1 x ActiV base sounder
- 1 x lid for base sounder
Optional decor plates available for use with ceiling mounted ActiV devices to cover the decorating marks left when used to retrofit older Grade D alarm devices.
Watch the Video
Why Hush-ActiV?
SAFER
Raises the typical level of fire protection in a dwelling from BS 5839-6 Grade D (unmonitored Mains/Battery Alarms) to Grade C (monitored wiring and a central controller)
EASY-TO-ACCESS USER CONTROLS
No need to stand on a chair to Test or Hush/Silence devices
SECURE MONITORED WIRING
All field wiring monitored for open and short circuit faults
ENVIRONMENTALLY FRIENDLY
Up to 50% reduction in the mains power consumption of a typical Grade D system, less plastic and only one replaceable lithium-ion battery per system providing over 72 hours standby
REDUCED LIFETIME OWNERSHIP COSTS
Separate fire detectors and sounders are less expensive to replace than Mains/Battery Alarms and all smoke detectors have built-in drift compensation to increase service life expectancy
NO INTRUSIVE BS 5839-1 MAINTENANCE VISITS
Monthly user/occupant test is sufficient
DIRECT GRADE D SYSTEM UPGRADES
Utilises the same wiring scheme as most Mains/Battery Alarm solutions
Hush-ActiV Operation
Press HUSH when there is an Unwanted Alarm to silence the system for 2 minutes (extendable by a further 2 minutes if the Alarm has not cleared). Press TEST for 3 seconds when the system is in its normal state to briefly sound the Alarm sounder(s). BS 5839-6 2019 recommends this test is carried out by occupants at least once a month.
Press HUSH when a wiring or battery fault is detected to silence the fault buzzer for 24 hours. Occupants should report the fault to the responsible person/service engineer at their earliest convenience.
Press HUSH when the system is in its normal state to deactivate alarm detection for 15 minutes (’hot works’ function).
Key Features |
---|
> Grade C domestic fire detection & alarm system to BS 5839-6 (2019) for use in individual flats, houses and apartments > Supplied as a cost-effective kit for ease of specification. > Easily accessible HUSH and TEST buttons > Monitored for battery, power supply, detector removal & open/short circuit faults. > Low-level system controller facilitates compliance with the Equality Act. > Attractive double gang Hush-ActiV controller comes with non-latching fire and fault outputs, a trigger input, a rechargeable 72 hour standby battery and a separate mains power supply unit > Uses attractively designed EN54 certified detection and alarm devices > Only one 10-year replaceable standby battery per system (supplied) > Each kit includes all of the devices you need to create a typical LD2 dwelling system - additional ActiV detection and alarm devices are also available to accommodate larger systems > Can be used in any situation where Grade D Mains/Battery Alarms are specified. > Kits with a different mix of fire detectors also available. |
Manufacturer | C-TEC |
---|---|
MPN | HAK/1 |
EAN | 5056059613277 |
Write Your Own Review
Sort By:
No questions yet. Be the first to ask the question!
Compatibility | Compatible with C-TEC's ActiV range of conventional fire alarm devices. For the contents of this kit, see Kit Contents section below. |
Total output current limited to | 100mA |
Battery charge capacity | 2Ah. |
Quiescent current | 5mA. |
Max battery size and type | 2Ah Li-Ion battery supplied (replaceable, up to 10 year life). |
No. of detector zone circuits | 1. |
No. of conventional sounder circuits | 1. |
Indicators | 4 x LEDs on Hush Controller: Supply (green); Fault (yellow); Alarm (red); Hushed (amber). |
Controls | 1 x TEST button; 1 x HUSH button. |
Expansion connections | 1 x unmonitored open collector Fire output (follows the dwelling's sounders but ignores system Tests); 1 x unmonitored open collector Fault output; 1 x unmonitored Alarm trigger. |
Onboard Sounder | Yes. Provides audible feedback of a fire/fault condition. |
Product dimensions (mm) | Hush Controller: 146 W x 85 H x 25 D mm (Can be mounted on a standard UK 35mm double gang flush or surface back box). |
Construction & finish | Supplied on a double gang plastic plate. |
IP Rating | IP40. |
Weight | 160g. |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95%. |
Kit contents | Includes a Hush-ActiV central controller, a 230V/24V PSU, one ActiV heat detector, one ActiV smoke detector, one ActiV multi-sensor, three ActiV detector bases and an ActiV alarm sounder. |